Water heaters: fire tube boilers series KCVa-(ECO)

КSVa-0,25 (ЕCО), КSVa-0,63 (ЕCО), КSVa-1,0 (ЕCО), КSVa-2,0 (ЕCО), КSVa-3,15 (ЕCО)

Fire tube boilers series KCVa-(ECO)


Fire tube boilers series KCVa-(ECO)
KSVa series (ECO model) steel automated fire-tube hot-water boilers are designed for heating and hot water supply to residential, industrial and office buildings in the closed heat-supply systems. The essential difference of ECO type boilers from the similar mass-produced fire-tube boilers is use of multi-layer internal thermal gastight front door, and special heat-resistant concrete, developed with the participation of specialists of the Kiev National University of Construction and Architecture. This modernization allowed increasing life span and time between overhauls for boilers.

Indicators

Rating heat

capacity

MW, not less

Fuel

Efficiency, %

The adjustment range is relatively nominal heat output%

Maximum water pressure, MPa

Minimum pressure boiler water inlet, MPa

Maximum temperature of the water outlet of the boiler, °С

The minimum water temperature at the inlet to the boiler

Water consumption m³/h, not more

Boiler hydraulic resistance, MPa, not more

Water volume boiler, m3

Heating surface m²

Flue gases minimum temperature

The pressure in the furnace, Pa, not more

Weight, kg, not more

Length, mm

Width, mm

Height, mm

КSVa-0,25 (ЕCО)

КSVa-0,63 (ЕCО)

КSVa-1,0 (ЕCО)

КSVa-2,0 (ЕCО)

КSVa-3,15 (ЕCО)

0,25

0,63

1,0

2,0

3,15

Liquid gas GOST 5542

91

91

91

91

91

40-100

30-100

40-100

40-100

30-100

0,6

0,35

0,2

0,35

0,35

0,35

115

60

4,8

12,7

19,1

38

60,2

0,03

0,05

0,03

0,03

0,03

0,28

1,08

1,08

1,19

2,7

6,53

14,98

20,3

47,8

68,7

160

160

160

160

160

300

400

600

600

600

950

1660

2740

4100

6500

2380

3140

3500

4130

4890

890

900

1300

1680

1860

1420

1840

1760

2660

2310


Press the left mouse button to turn!