Section has not been found.
Indicators |
DKVR-4-13 |
DKVR-6,5-13 |
DKVR-10-13
|
DKVR-20-13
|
Rating steam generating capacity t/h |
4,0 |
6,5 |
10 |
20 |
Steam temperature,°С |
194 |
|||
Steam pressure at boiler outlet, MPa |
1,3 (13) |
|||
Estimated fuel |
natural gas/mazut/coal |
|||
The estimated fuel consumption at rated load (natural gas, m° / h), no more |
297 |
444 |
740 |
1470 |
The estimated fuel consumption at rated load (mazut, kg / h), no more |
281 |
420 |
700 |
1400 |
The estimated fuel consumption at rated load (coal, kg / h), no more
|
450 |
726 |
1100 |
2290 |
Efficiency (natural gas), % |
90 |
91 |
91 |
92 |
Efficiency (mazut), % |
88,8 |
89,5 |
89,5 |
90 |
Efficiency (coal), % |
82,1 |
83,1 |
83,6 |
83,6 |
Length, mm
|
7203 |
8526 |
8850 |
11500 |
Width, mm
|
4590 |
4695 |
5830 |
5970 |
Height, mm
|
5018 |
5530 |
7100 |
7660 |
Boiler weight (coal), kg
|
8170 |
12 025 |
16 349 |
43 419 |
Boiler weight (natural gas, mazut), kg
|
8876 |
11206 |
15396 |
44634 |